be careful! small tube-like wire is vulnerable clogged and broken |
deadlocked, the most common is due to clogged by dirt particles carried with refrigerant (Freon), something which is natural because dirt particles or powder derived from iron that has been mixed with oil, as an example we can see the current engine oil change or car , from there we can see how the oil is already dirty it looks no small grains silvery, which meant that the iron powder which also occurs in the cooling system.
When refrigerant is pumped, a bit of oil that has been mixed with dirt is carried circulates, iron powder with a slightly larger size will be netted by the strainer or filter dryer to a more subtle but will pass through the capillary tube, evaporator and back into the compressor, because the process occurs continuously, it will form a layer of dirt that sticks to the inner walls of the capillary system and is certainly the most likely to experience a deadlock.
As a result of all this, the cooling system will experience a decrease in employment, among them is his cold reduced, noise and vibration compressor harder, rarely ceased operations, and other wasteful electricity.
To address this need not be quite easy because there are some tests and preparations to be made, which is the main course of his condition compressor should still feasible to re-use, then drain or flushing the entire system consisting of a condenser, filter dryer, evaporator capillaries and this should completely clean, if you can not meet these requirements in the near future the system will experience the same thing that is clogged capillary tube or worse.
These are literally the best ideas to decide to hire which technician for your refrigerator or which is the right choice for you? Heating and Cooling Toronto
ReplyDelete